Curtis Superior and SAF-AIR valves are designed for installation in a standard NPT port for NPT threaded valves or an AND-10050 style port for UNF threaded valves. Use a thread sealant or Teflon tape on pipe threaded valves. Never allow any thread sealant on the first thread . This will prevent contamination of the fuel system. Refer to aircraft manufacturer's torque specifications for the aircraft in which it is being used.
Replace the rubber seals as per the aircraft manufacturer’s recommendations or every ten years when no guidance is given. McFarlane stocks replacement seals and seal kits for both Curtis Superior and SAF-AIR valves. The new Curtis valves use a O-ring type seal instead of the flat seal that was previously used.
SAF-AIR valves are designed to be disassembled and the O-rings replaced. Over time, if the valve should start to leak, check to make sure the drain valve is tight. If drain valve is found to be tight, then check the O-rings. All O-rings used are buna "n", MS29513 Style, MIL-P-5315. SAF-AIR O-ring seal kits are available for most of their valves. Add a "K" or "-K" suffix to the valve part number.
Never have a hose attached in flight to the oil drain valve. Engine vibration and the additional attached mass can cause premature seal and valve wear which could result in valve failure and a loss of engine oil.
For non-certified aircraft only.
Thread | Locking | Hose Adapter Size | Open Action | Material | Approval |
5/8-18 UNF | Yes | 3/8" | Push | Aluminum | FAA-PMA |
Curtis Superior Valve Co. Inc. has produced, engineered, manufactured, and tested aircraft valves to exacting standards since 1944. They have many standard valves to solve a wide range of problems.
Thread: "UNF" (Fine thread) type are straight, non-sealing threads that rely on an o-ring to provide a seal. "NPT" (Pipe thread) type are tapered thread that seal as they are tightened. Others are metric threads. Measure the O.D. of the thread on the valve you are replacing and compare to the thread specifications table to determine the correct thread size.
Open Action: "Spiral" valves require a push and turn action to open. "Push" valves require a push action to open.
Hose Adapter Size: A hose may be attached to the valves for ease of draining. The size indicated is the hose I.D.
OUR PARTS ARE ENGINEERED TO LAST LONGER WHILE SOLVING KNOWN SAFETY ISSUES
OVER 40,000 PARTS IN STOCK WITH SAME DAY SHIPPING IF ORDERED BY 3PM
OUR TEAM PROVIDES THE OLD-FASHIONED CUSTOMER SERVICE THAT YOU EXPECT
View our search tips page, support page or please contact us.
Or, try our chat feature, located on the right side of our website during business hours. We welcome your comments and suggestions.